DOCUMENT BOUNDARY58CVA / 58CVX · Series 160

Check the rating plate and the control’s service label. Do not apply this table to a different series or a code from another system.

Carrier manual58CV-13SIEdition 09/13 · checked 2026-09-24
Flash-pattern helper

Count short flashes, then long flashes.

For this control, the manual uses short flashes as the first digit and long flashes as the second. Read the amber LED through the blower-door sight glass; do not open a service panel to use this tool. Manufacturer description, p. 47 ↗

Enter the two counts to find the matching row.
Manual index

Codes in this document

17 source-linked labels

This filter runs in your browser. All rows remain visible without JavaScript.

CodeManufacturer labelReference
11NO PREVIOUS CODEContext for this status Manual p. 57
12BLOWER ON AFTER POWER UPContext for this status Manual p. 57
13LIMIT CIRCUIT LOCKOUTManual p. 57
14IGNITION LOCKOUTManual p. 57
15BLOWER MOTOR LOCKOUTManual p. 57
21GAS HEATING LOCKOUTManual p. 57
22ABNORMAL FLAME-PROVING SIGNALManual p. 57
23PRESSURE SWITCH DID NOT OPENManual p. 57
24SECONDARY VOLTAGE FUSE IS OPENManual p. 57
25INVALID MODEL SELECTION OR SETUP ERRORManual p. 58
31HIGH-HEAT PRESSURE SWITCH OR RELAY DID NOT CLOSE OR REOPENEDManual p. 58
32LOW-HEAT PRESSURE SWITCH DID NOT CLOSE OR REOPENEDManual p. 57
33LIMIT CIRCUIT FAULTManual p. 57
34IGNITION PROVING FAILUREManual p. 57
41BLOWER MOTOR FAULTManual p. 58
43LOW-HEAT PRESSURE SWITCH OPEN WHILE HIGH-HEAT PRESSURE SWITCH IS CLOSEDManual p. 57
45CONTROL CIRCUITRY LOCKOUTManual p. 57
Read with care

A label is not a failed part.

Several entries name circuits, switches or lockouts. That is the wording of a control status, not evidence that a specific component must be replaced. A code on another model may have a different meaning.

Safety boundary

Do not use this as a repair procedure.

The cited manual reserves installation and service for trained, qualified personnel. If the system has an active fault or unsafe condition, follow the manufacturer’s safety instructions and contact a qualified HVAC professional.

Source: Carrier 58CV-13SI, Edition 09/13, printed pp. 47 and 57–58. This site is independent of Carrier. How we handle evidence →